*MAK 2191 model is next version of MAK 911 M model. Which was designed & developed at IITB- ,Science & technology park in 1991.* This GC still working in many industries for last 20-25 years.
New MAK GC 2191 can be used in different chemical industries like Solvent distillation plants , pharma intermediates R&D labs, etc. The modular and rugged designed (with FID ,TCD detectors ,& packed & capillary Columns) makes it versatile for many applications. Also available accessories like Head space sampler, Methaniser, Pyroliser, Sampling systems for LPG. Chromatography software, etc.
The MAK ANALYTICA 2191 is suitable for Quality control, R & D, routine analytical requirements and most of the applications. The modular concept for additional accessories, facilities, detectors and serviceablity.
Temperature Control
Modular construction makes the instrument versatile to upgrade with add-on modules as and when required in future . This also makes it convenient from service point of view so as to keep the down time to the minimum.
With our prompt after - sales service and application support, we have wide customer base in all kinds of industries.
Flame Ionization Detector is designed to give high sensitivity, while Thermal conductivity Detector is with minimum cell volume to get maximum sensitivity.
Techinical Specifications
Column Oven
Dimensions : 300 x 250x 150, (WxHxD)
Capacity : Any type of two columns
Operating Temperature : Adapters for, off-column with quartz liner for 1/8" SS column, On-column for 1/8" SS, 1/4" glass columns, Split /split less with quartz liner for capillary/mega bore columns.
Temperature Stability :
- + 0.1 ° C
- Accuracy : + 0.5 ° C
- Temp Profile more than 10 steps
- Method Storage : more than 60 files,
- Heating rate - 0.1 ° C/min to 40 ° C/min
- Column limit tem. adjustable
- With over heat protection
- Fast Auto cooling.
Injectors: Dual
Operating Temperature :
- 50° C to 400 ° C
- Adapters for,off-column with quartz liner for 1/8" SS column, On-column for 1/8" SS, 1/4" glass columns, Splot/split less with quartz liner for capillary/mega bore columns.
Detectors :
- Flame Ionisation Detector (FID) : Dual
- Operating Temperature : 50 ° C to 400 ° C
- Sensitivity : > 0.022 coulombs/gm
- MDL : <5 x 10 -12 gm c/sec Xylene
- LDR : 10 7
- Electometer Amplifier Sensitivity : 1x10-12 Amps / MV
- Thermal Conductivity Detrctor (TCD) : Dual Pass
- Operating Temperature : 50 ° C to 400 ° C
- Filaments: Tungsten-Rhenium,
- TCD control : Constant filament temperature mode (Adjusts current as per carrier gas TC, + Over-load protection for filament safety)
Other Available Detectors : NPD, ECD, DID, FPD, PID
Pneumatics
- Carier pressure switch for safety
- Pressure controllers & guages for, carrier, H2, Air
- Shut-off valves for H2, air
- Flow controllers (Options)
- Fine needle valves, DFC, EPC
Out-put signal (options)
- Analog : 0-1 volt
- USB with chromatography software
Power
- 230 V ac - 50 Hz, 2 KW
Dimensions:
- 565x 475x485 (WxHXD)
Weight: 45kg
GC Accessories
- Capillary Columns
- Packed Columns
- Glass Columns
- Syringes
- Syringe Cleaner
- Septum
- Phenumatic Fittings
- Flow Controllers DFC/EPC
- Gas Sampling Valve
- Manual, Auto
- Gas Filter Stations
Allied Equipments
- Methaniser
- Pyrolyser
- Head Space Sampler
- Thermal Desorption System
- Sampling System for LPG (ASTM)
Dedicated Gas Analyzer
- Binary Gas Analyzer*
- Multi Gas Analyzer*
- THC Analyzer*
- LPG Gas Analyzer*
- Natural GAs Analyzer
- Oxygen Meter
- Dew Point/Moisture Meter
Software
- Chromatography data Acquisition Software*
- laboratory Information Management System
- Calorific Valve Calulator fo LPG & CNG
- Customised Software